Timers and Programmers
Smart 6 Input Timer CDD Mk 2
Operating Instructions
Smart 6 Input Timer CDD Mk 2
Operating Instructions
Wiring Colour Codes230 volt Input & Output 230 volts , normal European colour codes
Low volt output and input cables, 8 core cable
Colour Outputs Inputs
Red Common (+ve) Remote Start Black 12v dc Alarm (-ve) Remote Start Grey 12v mechanical counter 1 Speed Purple 12v mechanical counter 2 Speed Orange 12v mechanical counter 3 Switch 2 (Black) Brown 12v mechanical counter 4 Switch 2 (Black) Yellow 12v mechanical counter 5 Switch 1 (Red) Blue 12v mechanical counter 6 Switch 1 (Red)
Showing the on-screen CountPress sw1 (red button), to show the count . Keep pressing to scroll through the 6 counts and the total .
Note that individual counts can be in either units or cash value and the total can be in either units or cash value (see programming notes)
On Screen ProgrammingHold the Red button (sw1) and Black button (sw2) simultaneously for 5 seconds to go into programming mode. The screen will display the version number of the software ( - 4.1 -) and then change to OP_1 t1 when the buttons are released.
Press the Red to scroll through the operations, press the Black to go into an operation to change the value, press Black again to change the value. Press Red to move onto the next operation.